![]() ![]() Now you run new cables from here to the voice / data outlets in the modular furniture. So inside the box, you can mount the category rated 110 blocks to match the existing cables and terminate them to one side of the block. You can even get these with power if you want to mount a switch here as well. They blend in with the ceiling tiles and open down for easy access. These boxes mount in the 2×2 or 2×4 ceiling grid and can be installed in the area above where the cut cables are to short to reach the modular furniture. If you planned to put modular furniture back in the open space, there is a great solution called a Zone Cabling Box (ZCB). However, if they are category 5e cables or above there are some choices to be made other than pulling all new cables. Now if these cables are old category 3 or category 5 cables, they are not worth keeping due to newer faster switches and VoIP phone systems. ![]() And let’s say the rack and patch panels are still present in the main distribution frame (MDF), also known as the server room, computer room or data room etc., and all the cables are still terminated on the patch panels. Whoever removed the cubicles just cut off the cables. ![]() You are moving into an existing facility and there is an open area where cubicles used to be. Most situations usually happen if you are looking at moving your company into an existing building that has some cut cables. Repeat steps 1 through 3 for the other cable that you need to splice.I have been in the business of installing voice, data and fiber optic cabling for about 30 years and I have been asked this question many times. Insert the cable with the crimp-ring loosely mounted into the compression tool where indicated and squeeze the handle to crimp the ring over the cable and connector. It will generally have the capability to be used for RG6 and RG59 coax type connectors, as well as other non-coax compression connectors. Your compression tool will have adapters for your cable type. Step 4 - Adjust and Employ Your Compression Toolįor this step, a specialized tool will firmly seat the crimp-ring onto the ends of the coax cable over the inserted part of the connector. The center copper wire should protrude just slightly beyond the end of the connector. Slide the compression connector onto the cable, being careful to not damage the protruding copper wire. Step 3 - Install the Compression Connector Your cable is now ready for the connector. Fold the mesh jacket back over the outer cable casing so that the insulator is bare. When you have completed the stripping you will have a cable with an exposed white insulator covered by a wire mesh jacket with a copper wire protruding. Coax cables are not the same as other electrical cables and the coax cable stripper is built to accommodate and strip the layers of the cable without cutting or damaging the innermost copper wire, which will ultimately protrude in order to mate with the female barrel coupler. ![]() The stripping tool will accommodate different sizes of coax cable and will have an adapter to accommodate your cable type. It is important to use a coaxial cable stripper to strip the coax cable, exposing about a half-inch. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |